ELECTRICAL SYSTEM
Hall Effect Board Replacement Guide:
1.
Turn off machine.
2.
Unplug 4
-
pin connector from back of board.
3.
Remove two #6
-
32 nuts and two #6 washers.
4.
Lift board off of mounting posts.
5.
Lower replacement board over posts.
6.
Replace washers and loosely thread on nuts.
7.
Rotate actuator until Actuator Magnet is perfectly centered over
Centering Post.
8.
Align Board Center Line mark with Actuator Magnet center as close-
ly as possible.
9.
Tighten nuts.
10.
Reconnect 4
-
pin connector to new board.
11.
Turn machine back on and test trip points as follows:
a.
Very slowly turn actuator clockwise, watching the
“
SW1 Out
”
LED towards the back of the board. The LED
should light at some point before the actuator magnet reaches the far left position.
b.
Slowly allow the actuator to return to center. The
“
SW1 Out
”
LED should turn back off before the actuator
reaches its center resting position (note that the actuator will never quite return to the exact center on its
own, though it should get fairly close.)
c.
Slowly turn the actuator counter
-
clockwise, watching the
“
SW2 Out
”
LED. The LED should light at some
point before the actuator magnet reaches the far right position.
d.
Slowly allow the actuator to return to center. The
“
SW2 Out
”
LED should turn back off before the actuator
reaches its center resting position.
Actuator Magnet Replacement Note:
For the Hall Effect Board to read the Actuator Magnet position,
the magnet must be oriented properly. Replacement magnets
will come marked with a solid stripe on the top face of the mag-
net. Magnet orientation can also be verified with a compass as
shown to the right.
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...