![Synesso MVP Technical Manual Download Page 23](http://html.mh-extra.com/html/synesso/mvp/mvp_technical-manual_1420889023.webp)
23
Milk Steaming
1. Fill the pitcher halfway with fresh, cold milk. Smaller pitchers are recommended for drink sizes less than 10
oz.
Note:
Steamed, unused milk should be discarded and the pitcher rinsed before reusing.
Note:
Whole Milk, 2%, 1%, Non
-
Fat, Soy Milk, Rice Milk and other milk type products may require different
techniques to foam properly. In general, the higher the fat content, the easier it is to steam.
OPERATION
Display Errors
Save Lockout is on
See Page 51 to Unlock
Steam Tank, Low Water
Level or Low Flow Error
Low Water Level is Ac-
companied by a beeping
noise. See Trouble-
shooting Guide starting
on Page 72
5 Minute Time Out Er-
ror or Low Flow Error
Shift the group top han-
dle to clear. For Low
Flow Error see the Trou-
bleshooting Guide
starting on Page 72
Shot Timer Test Mode
, all
functions cycle on display.
Shot timer requires service
Using the Save Function Continued...
Note:
The following functions do not change the memory of the last brewing function:
•
Turning on save mode (hold any brew group handle right for 2.5 seconds)
•
Shifting thru the 6 available programs (momentary presses of the brew group handle to the right)
•
Saving (momentarily pressing the brew group handle left from within save mode)
•
Saving again to additional program locations, on the same, or different groups
•
Exiting save mode (hold any brew group handle right for 2.5 seconds)
•
Shifting between programs M, MP, VP, by holding the handle on the desired brew group left
When a running group is stopped, the parameters are stored. After shot parameters are saved they can be
viewed and altered on the handheld controller. Any alterations are saved as new shot parameters.
Display Errors:
Each shot timer is capable of indicating one of several possible errors received from the machine. These er-
rors are always accompanied by a red triangle. See the images below for information regarding each error.
The errors displayed by the shot timers do not represent all of the possible errors that the machine can reg-
ister. Please refer to page 43 for a list of further errors that can be logged in the machine programming.
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...