39
PROGRAMMING
Overview:
This programming section applies to all MVP Series Synesso
™
machines. MVP Series machines have a wired
handheld controller (pictured below) that allows the user to easily view and change the machine settings.
To change settings on these screens, first press the line button on the left side of the display associated
with the setting you wish to change. The value will flash once selected. Press the up or down buttons until
the desired value is displayed. Press the line button again to confirm the change. The value will stop flash-
ing. Use this procedure to change any variables in the controller menus.
The top line of every screen indicates the title. In this case, Temperature Overview.
You can return to this screen at any time by pressing the home button at the top right of the controller.
The machine will also return to this screen automatically after a short time.
Lines 2, 3, and 4 may contain information or settings, many of which can be changed by the operator. This
screen provides the current temperatures for each brew group along with the steam tank. The most recent
error will also be shown in the lower right corner. No settings can be changed on this screen.
In some circumstances, numeric temperatures will not be shown. If a tank is reading
‘
LOW
’,
this indicates
that the tank is below the temperature probe
’
s effective range of measurement (170°F
-
270°F / 76.6°C
-
132.2°
C). Readings above the effective range will show as
‘
HIGH
’.
The programmable temperature range for a brew group is from 180°F (82.2°C) up to 220°F (104.4°C). The
factory set temperature is 203°F (95°C). To change brew group set temperatures, refer to page 40.
The steam tank is set in factory to a default setting of 250°F (121.1°C). To change this temperature setting,
see page 41.
The [OK] on the right hand side of line 4 is indicating that there have been no errors detected by the control
system. If, in place of the [OK] you find an error code (Ex: STLW01), refer to the Error Log codes on page 43.
To cycle to the next display screen, press the down arrow button. (You may press the up arrow instead to
travel back to the previous screen.)
Line 2 Button
Line 3 Button
Line 4 Button
Home
Up
Down
Line 1 Title
Menu Level 1: Temperature Overview; Home Screen
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...