Chapter 1 Getting Started
Performing Basic Tasks
Operating and Programming Manual
11
While the sync input is armed,
all 1pps outputs and the clock display are stopped.
These resume on synchronization or within 1.5 seconds, whichever occurs first.
If no sync pulse is captured within 1.5 seconds after arming, the selected sync
input is disarmed, and the instrument's LCD display shows: Sync timed out.
Setting Time and Date
To Set Time
1
Press
Shift
, then
8
(Set Clock).
2
Set 24-hour time
3
(numeric keys), then press
Enter
: the time displays increment
immediately.
3
Press
to select the Display ON/OFF field, then press
Inc
to turn on the Display.
To Set Date
1
Press
Shift
, then
8
(Set Clock).
2
Press
twice to select the DATE field.
3
Enter the Modified Julian day
3
with the numeric keys.
4
Press
Enter
.
The new date is shown in the LCD display.
Always synchronize the 1pps pulse outputs before setting time and date, otherwise the
clock may display incorrect time/date information.
Powering Down the 5071A
When removing power from the 5071A, you'll need to disable the internal-standby
battery. (Note: 48V option does not have internal-standby battery).
If the 5071A is used in a system or operation where power is removed on a daily or more
repetitive basis, it is strongly recommended that the internal standby batteries be
physically disconnected (this step is not required for 48V option instruments). This will
prevent excessive discharge/recharge cycles from prematurely depleting standby capacity.
Refer to page 28 for the information on how to disable the internal-standby battery.
3
See pages 19 and 20 for information about the Modified Julian Day (MJD).
NOTE
Summary of Contents for 5071A
Page 2: ......
Page 28: ...Preface xxvi Operating and Programming Manual ...
Page 29: ...____________________________________________ Chapter 1 Getting Started Getting Started ...
Page 32: ...Chapter 1 Getting Started The 5071A at a Glance 4 Operating and Programming Manual ...
Page 33: ...Chapter 1 Getting Started The 5071A at a Glance Operating and Programming Manual 5 ...
Page 40: ...Chapter 1 Getting Started Performing Basic Tasks 12 Operating and Programming Manual ...
Page 41: ...____________________________________________ Chapter 2 Using the 5071A Using the 5071A ...
Page 97: ...____________________________________________ Chapter 5 Command Reference Command Reference ...
Page 119: ...Chapter 5 Command Reference Description of SCPI Commands Operating and Programming Manual 91 ...
Page 136: ...Chapter 5 Command Reference Error Messages Codes 108 Operating and Programming Manual ...
Page 137: ...____________________________________________ Chapter 6 Specifications Specifications ...
Page 145: ...____________________________________________ Chapter 7 Installation Installation ...
Page 162: ...Chapter 7 Installation Cesium Beam Tube Replacement 134 Operating and Programming Manual ...
Page 186: ...Appendix A Performance Tests 5071A PERFORMANCE TEST 158 Operating and Programming Manual ...
Page 187: ...____________________________________________ Appendix B Glossary Glossary ...
Page 190: ...Appendix B Glossary 5071A Glossary 162 Operating and Programming Manual ...