4-19
Spectrum24 Terminal Setup
4. Press <ENTER> on the host PC to start the download. The 384X displays:
Program loader
Status XXXX
5. When the transmission is complete, the 384X displays:
Program loader
Status 0000
A status of 0000 (all zeroes) indicates a successful transfer. If the status is other than
0000, check the cable connections between the host PC and the cradle and repeat the
process. If the problem persists, contact the Symbol Support Center for assistance.
6. When the download is complete, the Series 384X displays the following query:
LWP.HEX Ver X.XX
Loading system files
1. Reformat flash
2. Use flash as-is
Select [1,2]:
Caution
Reformatting the flash removes all system files and applications stored on
the flash disk.
Select 1, Reformat flash, ONLY if you have problems with the Series 384X’s
operation. Select 2, Use flash as-is, to update the flash while retaining the
existing contents.
7. If you select 1, the 384X displays the message:
Are You sure Y or N
8. Press Y to continue with the reformat or N to cancel and press <ENTER>.
The Series 384X finishes reformatting (if requested), copies the files to the flash disk,
and executes them.
Summary of Contents for Series 3800
Page 1: ...Series 3800 Product Reference Guide...
Page 3: ...Series 3800 Product Reference Guide...
Page 4: ...4...
Page 5: ...Series 3800 Product Reference Guide 70 32230 01 Revision B May 2001...
Page 12: ...viii Series 3800 Product Reference Guide...
Page 62: ...4 22 Series 3800 Product Reference Guide...
Page 90: ...6 12 Series 3800 Product Reference Guide...
Page 108: ...B 2 Series 3800 Product Reference Guide...