4-16
Series 3800 Product Reference Guide
Updating System Software on Flash Disk
Updating the LWP hex image means loading the new system files on the flash disk using the
SENDHEX utility on a PC. It is possible to perform this update on multiple terminals in a
cradle at one time, with each terminal running Program Loader from Command Mode.
Note:
The Series 384X is shipped with the LWP hex file installed. Use this
procedure ONLY:
•
to load a new version of LWP greater than 3.03
•
if you experience serious difficulties
•
if you are so directed by Symbol’s Technical Support staff.
Option: Using _L.BAT to Update System Software
If the Series 384X terminal contains a LWP hex file of version 3.03, you can follow the
instructions for installing application software on the flash disk using _L.BAT through step
6, when the terminal is reinitialized. Proceed to step 6 of this procedure at that point.
Note: Be sure, when entering the SENDHEX command on the PC, to issue
the command from the directory where the hex file (LWP.HEX) is
stored.
Initiate Host Communications on the PC
To update the system software:
1. Power on the host computer.
2. On the PC, change to the directory where the system hex file (LWP.HEX) is stored
and type the following command at a DOS prompt:
SENDHEX LWP 384 [1|2] <ENTER>
Summary of Contents for Series 3800
Page 1: ...Series 3800 Product Reference Guide...
Page 3: ...Series 3800 Product Reference Guide...
Page 4: ...4...
Page 5: ...Series 3800 Product Reference Guide 70 32230 01 Revision B May 2001...
Page 12: ...viii Series 3800 Product Reference Guide...
Page 62: ...4 22 Series 3800 Product Reference Guide...
Page 90: ...6 12 Series 3800 Product Reference Guide...
Page 108: ...B 2 Series 3800 Product Reference Guide...