7-12
Series 3800 Product Reference Guide
8. Specify the baud rate. Use the UpArrow and DownArrow to scroll through the list
of baud rates until the correct rate is displayed and press <ENTER>.
Note: Flow control may be necessary at 38400 bps and higher.
9. Specify the data bits. Press <7> or <8>, or use UpArrow and DownArrow to display
the values 7 or 8 and press <ENTER>.
Note: If you select 8 data bits, the program selects No parity and skips the
next screen.
10. Specify parity type. Use UpArrow and DownArrow to display a parity option, or
press the first letter of a parity option (Even, Odd, None, Space, or Mark) and press
<ENTER>.
11. Set flow control. Use UpArrow and DownArrow to display the flow control options,
or press the first letter of an option ( None, Xon/Xoff, or RTS/CTS) and press
<ENTER>.
Start Communications
1. The terminal is ready to send the data to the host PC and displays:
Comm Parameters
Start? <ENT>
2. Verify that the host is ready to receive data.
3. Press <ENTER> on the terminal.
While data is being transferred, the terminal displays a report of the 1 KB range being
transferred:
Memory Transfer
Sending: XXXX
The display is updated for every 1024 bytes (1 KB) of memory.
Summary of Contents for Series 3800
Page 1: ...Series 3800 Product Reference Guide...
Page 3: ...Series 3800 Product Reference Guide...
Page 4: ...4...
Page 5: ...Series 3800 Product Reference Guide 70 32230 01 Revision B May 2001...
Page 12: ...viii Series 3800 Product Reference Guide...
Page 62: ...4 22 Series 3800 Product Reference Guide...
Page 90: ...6 12 Series 3800 Product Reference Guide...
Page 108: ...B 2 Series 3800 Product Reference Guide...