C-2
Series 3800 Product Reference Guide
Scanning
Standard 1-D Scan Element
Table C-2. Standard 1-D Scan Element Specifications
Item Description
Power Requirements
3.0 to 5.5 VDC; 60 mA typ @V
cc
; 70 mA max
Surge Current
60 mA typical @ 5.5 VDC; duration — 16 mSec
Cold Standby Current
50 mA
Max V
cc
Noise Level
100 mV p to p
Scan Repetition Rate
36 (± 3) scans/sec (bidirectional)
Laser Power
.9 mW max
Skew Tolerance
± 65
o
from normal
Pitch Angle
± 55
o
from normal
Specular Dead Zone
±2
o
Decode Depth of Field
Minimum element resolution is 5 mils (.127 mm)
Max Typical working distance is 34 in. (86 cm)
Print Contrast Minimum
20% absolute dark/light reflectance differential, measured at 675 nm.
Ambient Light Immunity
Immune to direct exposure from normal office and factory level light
Sunlight
8000 ft. candles; 86,112 lux with correct enclosure
Artificial Light
150 ft. candles; 1615 lux
Shock
1500 G applied via any mounting surface @23
o
C
Vibration
Withstands a sinusoidal vibration of 1 G along each of the 3 mutually
perpendicular axes for a period of 1 hr. per axis, over a frequency
range of 5 Hz to 2000 Hz.
Operating Temperature
-4° to 122° F; -20° to 50° C
Storage Temperature
-40° to 140° F; -40° to 60° C
Humidity
5% to 95% non-condensing
Height
0.76 in. max.; 1.93 cm
Width
1.60 in. max.; 4.1 cm
Length
1.49 in. max.; 3.8 cm
Weight
1.70 oz. max.; 48 gm
Summary of Contents for Series 3800
Page 1: ...Series 3800 Product Reference Guide...
Page 3: ...Series 3800 Product Reference Guide...
Page 4: ...4...
Page 5: ...Series 3800 Product Reference Guide 70 32230 01 Revision B May 2001...
Page 12: ...viii Series 3800 Product Reference Guide...
Page 62: ...4 22 Series 3800 Product Reference Guide...
Page 90: ...6 12 Series 3800 Product Reference Guide...
Page 108: ...B 2 Series 3800 Product Reference Guide...