E-18
Series 3800 Product Reference Guide
Field Diagnostics
During a field diagnostic test, the screen shown in Figure E-20 is displayed and continuously
updated.
Figure E-20. Field Diagnostics (Screen 1)
Each ping results in a new line being displayed, showing the cumulative ping count,
error count, retry count for this message, round-trip time in milliseconds for this
message or indication of error type if there was an error, and the AP identifier of the
AP that responded to the message.
When the test stops, a summary screen is displayed (Figure E-21).
Figure E-21. Field Diagnostics Summary Screen
Press <Q> or <CLEAR> to terminate the test and return to the DIAG24 menu.
FIELD DIAGNOSTICS
A Cnt Err
Rty ms
AP
56
2
0 165
52
57
2
0
55
52
58
3
1 TMO
52
59
3
0 220
52
55
2
0
55
52
Press ‘Q’ to Quit
FIELD DIAGNOSTICS
Total secs = 8.2
Pings = 100
Packet size = 512
Retries = 6
Timeouts = 4
[R]epeat or [Q]uit