6-3
Simple Serial Interface
PARAM_SEND
H/D
0xC6
Send parameter values.
REPLY_REVISION
D
0xA4
Reply to REQ_REV contains
decoder’s software/hardware
configuration.
REQUEST_REVISION
H
0xA3
Request the decoder’s
configuration.
SCAN_DISABLE
H
0xEA
Prevent the operator from
scanning bar codes .
SCAN_ENABLE
H
0xE9
Permit bar code scanning.
SLEEP
H
0xEB
Request to place the decoder
into low power.
START_DECODE
H
0xE4
Tell decoder to attempt to
decode a bar code.
STOP_DECODE
H
0xE5
Tell decoder to abort a decode
attempt.
WAKEUP
H
N/A
Wakeup decoder after it’s been
powered down.
Table 6-1. SSI Commands (Continued)
Name
Type
Opcode
Description
Page
Note:
D = Decoder, H = Host, H/D = Host/Decoder
Summary of Contents for SE 923
Page 1: ...SE 923 Scan Engine Integration Guide...
Page 3: ...SE 923 Scan Engine Integration Guide 70 37052 01 Rev A February 1999...
Page 10: ...viii SE 923 Scan Engine Integration Guide...
Page 16: ...xiv SE 923 Scan Engine Integration Guide...
Page 22: ...1 6 SE 923 Scan Engine Integration Guide...
Page 29: ...2 7 Installation Figure 2 3 Exit Window Positioning CASE 1 CASE 2...
Page 52: ...4 8 SE 923 Scan Engine Integration Guide...
Page 135: ...5 83 Parameter Menus Prefix Suffix Values DATA FORMAT CANCEL...
Page 155: ...5 103 Parameter Menus Numeric Bar Codes cont d 4 5 6 7...
Page 196: ...6 40 SE 923 Scan Engine Integration Guide...
Page 232: ...Glossary 8 SE 923 Scan Engine Integration Guide...
Page 236: ...Index 4 SE 923 Scan Engine Integration Guide...
Page 238: ......