5-56
SE-923 Scan Engine Integration Guide
Enable/Disable Code 39 Full ASCII
Parameter # 0x11
To enable or disable Code 39 Full ASCII, scan the appropriate bar code below.
When enabled, the ASCII character set assigns a code to letters, punctuation marks,
numerals, and most control keystrokes on the keyboard.
The first 32 codes are non-printable and are assigned to keyboard control characters such as
BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE
and DELETE produce visible characters.
Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39
character and assigns an ASCII character value to the pair. For example, when Code 39 Full
ASCII is enabled and a
+B
is scanned, it is interpreted as
b
,
%J
as
?
, and
$H
emulates the
keystroke
BACKSPACE
. Scanning
ABC$M
outputs the keystroke equivalent of
ABC
ENTER
. Refer to the Table B-5 on page B-7.
Code 39 Full ASCII and Trioptic Code 39 should not be enabled simultaneously.
The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.
ENABLE CODE 39 FULL ASCII
(0x01)
DISABLE CODE 39 FULL ASCII
(0x00)
Summary of Contents for SE 923
Page 1: ...SE 923 Scan Engine Integration Guide...
Page 3: ...SE 923 Scan Engine Integration Guide 70 37052 01 Rev A February 1999...
Page 10: ...viii SE 923 Scan Engine Integration Guide...
Page 16: ...xiv SE 923 Scan Engine Integration Guide...
Page 22: ...1 6 SE 923 Scan Engine Integration Guide...
Page 29: ...2 7 Installation Figure 2 3 Exit Window Positioning CASE 1 CASE 2...
Page 52: ...4 8 SE 923 Scan Engine Integration Guide...
Page 135: ...5 83 Parameter Menus Prefix Suffix Values DATA FORMAT CANCEL...
Page 155: ...5 103 Parameter Menus Numeric Bar Codes cont d 4 5 6 7...
Page 196: ...6 40 SE 923 Scan Engine Integration Guide...
Page 232: ...Glossary 8 SE 923 Scan Engine Integration Guide...
Page 236: ...Index 4 SE 923 Scan Engine Integration Guide...
Page 238: ......