<ENTER>
This push-button enables the user to enter the selected position shown on the screen Menu
list or to confirm selected settings. Some additional functions of this push-button will be
described in the following chapters of this manual.
(<Menu>)
This push-button (pressed together with
<Shift>
) enables the user to enter the main list
containing six sub-lists:
Function
,
Measurement
,
Display
,
File
,
Instrument
and
Auxiliary Setup
. Each of the mentioned above menu lists consists of sub-lists, elements and
data windows. These main sub-lists will be described in detail in the following chapters of the
manual. Double pressing the
<Menu>
push-button enters a list containing the last eight
opened sub-lists. It often speeds up control of the instrument as the user has faster access to
the most frequently used sub-lists for easy navigation.
[<Save>]
This push-button (pressed together with
<Alt>
) enables the user to save measurement results
as a file in the instrument’s internal memory or on the SD-card.
<ESC>
This push-button closes the control lists, sub-lists or windows. It acts in an opposite manner
to the
<ENTER>
push-button. When the window is closed after pressing the
<ESC>
push-
button, any changes made in it are ignored in almost all cases.
([Cal.])
This push-button (pressed together with
<Shift>
) opens the
Calibration
sub-list.
[<S/P>]
This push-button enables the user to jump to pause or break the measurement process
temporarily. If there is no current running measurement in progress this push-button opens
the Setup Manager menu
<
>
,
<
>
These push-buttons enable the user specifically to:
•
select the column in a multi column parameter list;
•
select the parameter value in an active position (e.g. filter Z, A or C, Integration period: 1s,
2s, 3s, … etc.);
•
control the cursor in Spectrum and Logger modes of result’s presentation;
•
select the position of the character in the text editing mode;
•
activate markers 2 and 3
•
speed up changing the numerical values of the parameters when pressed and held.
(<
>
,
<
>)
The
<
>
,
<
>
push-buttons pressed in conjunction (or in sequence) with
<Shift>
enable the
user specifically to:
•
speed up changing the numerical values of the parameters (i.e. the step is increased from
1 to 10 in the setting
of
Start Delay
-
path: Menu / Measurement / General Settings / Start
Delay
);
•
jump to the last or first character of an edited text line in the text edition modes,
[<
>
,
<
>]
The
<
>
,
<
>
push-buttons pressed in conjunction (or in sequence) with
<Alt>
enable the
user specifically to:
•
select the parameters value in the multi column list,
•
insert or delete a character in the text editing screen.
<
>
,
<
>
The
<
>
,
<
>
push-buttons enable the user specifically to:
•
select lines in the list;
•
select the correct character from the list in the text edition screen;
•
activate markers 1 and 4
(<
>
,
<
>)
The
<
>
,
<
>
push-buttons pressed in conjunction (or in sequence) with
<Shift>
enable the
user specifically to:
•
change relationship between the Y-axis and X-axis of all plots presented on the screen
[<
>
,
<
>]
The
<
>
,
<
>
push-buttons pressed in conjunction (or in sequence) with
<Alt>
enable the
user specifically to:
•
change the mode of result’s presentation;
•
programme the Real-Time Clock (
RTC
) and
Timer
;