Set-up
Technical Handbook
019722-101 Rev. 05
22
SC-350/360
7
Set-up
7.1 Master Reset
This option resets:
• All program values are set to their default values.
• All registers, except the statistics and service interval registers, are
set to zero.
• The batch stops are set to their default values: 20, 40, 50, 1000,
2000, 4000 and 5000.
To reset:
a) Press
Q
,
M
,
B
and
Start/Stop
at the same time, while switching
On
the machine.
b) When the display changes from showing “888888”s to a blank
display, release
Q
,
M
,
B
and
Start/Stop
.
c) Press and hold
C
. The display shows “r E S A L L”.
d) Release
C
. The display shows “888888” and then “r E S E E”.
Protection of master reset
It is possible to protect the master reset with a password. For further
details see