Adjustments
Technical Handbook
019722-101 Rev. 05
74
SC-350/360
11.3 Height Adjustment of the Coin Feed Belt
The coin feed belt should be able to feed the thinnest coin. The belt
assembly will automatically adjust to a correct level when turning the
thickness knob, but it must be synchronised with the thickness guide
block.
a) Open the inspection cover.
b) Tighten the locking screw (4).
c) Remove the screw and spacer (1).
d) Insert the washers (2).
Note!
The same number of washers must be inserted at the thickness guide
block as well.
e) Replace the screw and spacer (1)
f) Loosen the locking screw (4).
If the belt is in a too low position it will influence the counting
speed.
11.4 Feeding Belt Pressure
Note!
Refer to fig. above.
The feeding belt pressure can be adjusted with the adjustment
screw (4). The coin feed belt should grip and feed the thinnest coin.
1 Screw and spacer
2 Washer
3 Adjustment screw
4 Locking screw
1
2
3
4