Set-up
Technical Handbook
019722-101 Rev. 05
26
SC-350/360
(b) 0-2 Solenoid
Determines for how long time the solenoid remains active once the
machine has stopped. When set to
1
or
2
the solenoid is active for a
longer period of time. Avoid this if the machine is being used to
count small quantities (up to 20 coins) at a high repetitive speed.
(c) 0-6 Delay period and reverse period
Determines how long the delay will be after the solenoid no longer is
active, before the motor reverses. It also determines for how long the
motor reverses.
By altering this number it is possible to compensate for some
mechanical changes that occur during the lifetime of the machine.
The delay can be set in smaller steps in program version 4.00 and on,
see
“7 - Miscellaneous Functions #2” on page 30
.
(d) 0-2 Reversing sequence
Determines the characteristics of the automatic reversing sequence. A
lit up decimal point indicates that the automatic reversing function is
selected. If the function is not selected, the machine runs until it
stops.
Solenoid
0
On for 600 ms (default).
1
On until the motor has reversed.
2
On until the reversing sequence has ended.
Delay (solenoid)
Reverse (motor)
0
1000 ms (default)
50 ms (default)
1
500 ms
50 ms
2
1000 ms
150 ms
3
500 ms
150 ms
4
1000 ms
400 ms
5
500 ms
400 ms
6
The motor is not reversed, only the solenoid is activated, as if b)=0
above. Other values for b) do not affect the solenoid.
Reversing sequence
0
The motor runs for 5 s, reverses slightly and then runs for another
5 s before stopping (default).
1
The motor runs for 3 s, and then does a normal stop sequence.
2
This is a continuous sequence where the motor runs for 5 s, reverses
slightly and restarts.