Set-up
Technical Handbook
019722-101 Rev. 05
29
SC-350/360
(b) Zeroes RD (accessory) when C is pressed
(b) and (c) work independently.
(c) Zeroes RD (accessory) when M is pressed
(b) and (c) work independently.
(d) Adjusts Start/Stop-function
7.8 6 - Computer Communication
Press
Q
until the number “6” is shown at the far left of the display.
Example (default setting):
(a) Not used
(b) Debugging control programs
Disables the time out function of the machine. This function is used
for debugging control programs. (b)= 0 for normal machine
operation.
(c) One character via the serial port
Sends only one character via the serial port every time the CTS
changes from inactive (–12 V) to active (+12 V). Makes it easier to
implement PC control programs under Windows.
(d) Disables the handshake signals
Disables the handshake signals for serial port communication.
Start/Stop function
0
The machine starts and stops when the
Start/Stop
key is pressed
(default).
1
The machine starts when
Start/Stop
is released and
stops when
Start/Stop
is pressed.
2
The machine starts when
Start/Stop
is pressed for at least 1 second
and stops when
Start/Stop
is pressed for less than 1 second.
6
0
0
0
0
a (-)