Bringing the Benefits of Real-Time Data Collection to the World
Sutron Corporation, Tel: 703-406-2800,
http://www.sutron.com
214
Measure (Measure)
Inputs
Input
Outputs
Output
Description
Measure blocks are used to create a sampling schedule for sensor blocks. The only time a
Measure block (or similar) is not needed after a sensor block is when the sensor block is set to
output data based on a specified change on the sensor input (Event mode).
Enter values for the
Time
and the
Interval.
The interval is how often the data from the sensor
should be sampled. The time is a synchronization time (not an start time). In the example below,
the sensor will be sampled every fifteen minutes, synchronized to the hour. If
Time
had been set
to 00:01:00, the sensor would be sampled every fifteen minutes with a one minute offset – if
sampling was started at 4:00pm, samples would be taken at 4:16p, 4:31p, 4:46p, etc.
Sensor blocks configured in Event mode do not need to be hooked-up to Measure blocks, but
they can be if desired. Doing so will result in data being generated
either
because of a specified
change in the sensor input
or
because the next scheduled sampling time has arrived.
Summary of Contents for Xpert2
Page 2: ......
Page 11: ...Chapter 1 Introduction...
Page 16: ......
Page 17: ...Chapter 2 Getting Started...
Page 86: ......
Page 87: ...Chapter 4 Graphical Setup Diagrams...
Page 104: ......
Page 105: ...CHAPTER 5 EXAMPLE SETUPS...
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ...Chapter 7 Installation...
Page 140: ......
Page 141: ...Chapter 8 Maintenance and Troubleshooting...
Page 145: ...Appendix A Setup Blocks...
Page 266: ......
Page 267: ...Appendix B Updating the Firmware...
Page 290: ......
Page 291: ...Appendix E Software Development Kit SDK...
Page 293: ...Appendix F Creating Custom Voice Files...
Page 330: ......