Constant (ConstIn)
Inputs
<none>
Outputs
Const
Wiring
None
Description
The constant block provides a constant value output. This can be valuable for testing setup
diagrams before physical sensor are hooked-up, or in any other situation where a constant output
is needed. A constant value may be modified via calibration or by setting the value of a
connected ComsTag block using telemetry, the command line SET command, or the Data tab.
This allows a constant block to be used for manual readings and other purposes. Modified values
are stored back in to the setup file.
The
Read Only
check box may be used to prevent the constant value from being modified by
means other than direct modification of the setup.
The
Test
check box is used to generate data that varies. This can be useful for system tests. When
Test
is checked the data will vary as follows:
Constant
Output
1
TickCount (ticks have units of
milliseconds, not synchronized
to any particular time)
2
Random Number between 1
and 32767
3
Output increases by 1
Summary of Contents for Xpert2
Page 2: ......
Page 11: ...Chapter 1 Introduction...
Page 16: ......
Page 17: ...Chapter 2 Getting Started...
Page 86: ......
Page 87: ...Chapter 4 Graphical Setup Diagrams...
Page 104: ......
Page 105: ...CHAPTER 5 EXAMPLE SETUPS...
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ...Chapter 7 Installation...
Page 140: ......
Page 141: ...Chapter 8 Maintenance and Troubleshooting...
Page 145: ...Appendix A Setup Blocks...
Page 266: ......
Page 267: ...Appendix B Updating the Firmware...
Page 290: ......
Page 291: ...Appendix E Software Development Kit SDK...
Page 293: ...Appendix F Creating Custom Voice Files...
Page 330: ......