5600-0131-3, –4, -5 and 56-0131-50-1, -2 Models with Terminal Strip
The following table contains pin descriptions for the terminal block.
Description Terminal
Block
Notes
Pump Power IN Positive
1
+8 to +16 VDC (3 Amp)
Pump Power IN Ground
2
Pressure Sensor Pwr In +
3
+8 to +28 VDC
Pressure Sensor Pwr In -
4
SDI-12 Data
5
Analog output (A+)
6
0-5 VDC (only on –4)
Analog ground (A-)
7
Also can be used as ground for Quad. Out
Quadrature out Phase A
8
Phase A will lead Phase B for positive change (only on –
3)
Quadrature out Phase B
9
Phase A leads by going to 5V before Phase B (only on –3)
Note: Only the 5600-0131-3 and 56-0131-50-1 support Quadrature and only the 5600-0131-4 and
56-0131-50-2 support analog out.
5600-0131-5 supports SDI-12 output only.
The ACCUBUBBLE needs two power connections. The first is to a 12 VDC 3 A power source to power the
pump. The second is to power the pressure sensor. It is recommended that the pressure sensor power be in
common with the device reading the sensor. If the sensor is being read by an SDI-12 data recorder, then the
sensor power would come from the SDI-12 data recorder (SDI-12 defines a three wire connection of data,
12V, and Ground). The SDI-12 12V should be used for the internal SDI-12 sensor, but should NOT be used
to power the pump. The 12 VDC power supply for the pump needs to share a common ground with the SDI-
12 data recorder collecting data from the AccuBubble.
SDI-12 Data Recorder Connection
Description Terminal
Block
Notes
Pump Power IN Positive
1
+8 to +16 VDC (3 Amp)
Pump Power IN Ground
2
Sensor Pwr In +
3
SDI-12 Power line
Sensor Pwr In -
4
SDI-12 Ground Line
SDI-12 Data
5
SDI-12 Data Line
Analog output (A+)
6
Analog ground (A-)
7
Quadrature out Phase A
8
Quadrature out Phase B
9
Note: Connection to an SDI-12 data recorder does NOT preclude an additional Quadrature or
Analog output connection. The 5600-0131-5 supports SDI-12 output only.