Logging Temperature data from the ACCUBUBBLE
Temperature data is the first parameter the ACCUBUBBLE returns from the M2 command. Unless the units
of temperature have been changed from the factory defaults, the ACCUBUBBLE will return the temperature
in degrees C. To log the internal temperature of an ACCUBUBBLE that has been installed at address 5, the
following command must be issued:
5M2!
With the 8200 family the logged parameter came be named to help identify the data on future visits or upon
data retrieval. To issue the 5M2! command we are limited to a 5 character name. If “temp” is chosen as the
identifying name then the sensor should be named:
temp5_1M2
This name indicates that the M2 command should be issued to address 5 and the first parameter returned
should be logged.