Command
Description
Command Syntax
(command underlined)
ACCUBUBBLE response
(underlined)
"a" represents the single-
character address
XOM Set
operating
mode
aXOMm!
where m is the desired operating
mode. Values for m:
0 Bubbler Operation disabled
64
Bubbler operation.
72
Bubbler with quadrature output.
Quadrature output will only be
updated when an SDI-12
measurement is requested. Only
relevant for a 5600-0131–3 or
56-0131-50-1unit.
80
Bubbler with Analog output.
SDI-12 measurements not
required for the analog output to
be updated.
88 Bubbler with quadrature output.
SDI-12 measurements not
required for the quadrature
output to be updated.
Note: aXOM! Will cause the D0
command to return the current
operating mode
attt1
indicating that the command will take ttt
seconds to complete and that one (1)
value can be collected
NOTE:
A D0 command issued after the
XOM command will return the set
operating mode.
36
Summary of Contents for Accububble 56-0131-50-1