2-14
S
UPER S2QR6/S2QE6
User's Manual
Installation
Alarm Reset
Pin 33 of JF1 provides a connec-
tion for a switch to disable the
system's audible alarm, which in-
dicates either a chassis overheat
condition, a power supply failure
or a fan failure. The alarm reset
switch will only disable the audible
alarm; the alarm LED correspond-
ing to the alarm will remain illumi-
nated until corrective actions have
been taken. See Table 2-15 for
pin definitions and Figure 2-5 for
pin locations.
Pin
N u m b e r
3 3
Definition
Alarm Input
Table 2-15
Alarm Reset Switch
Pin Definitions (JF1)
Speaker
The speaker connection is located
on pins 28, 30, 32 and 34 of JF1.
See Table 2-14 for pin definitions
and Figure 2-5 for pin locations.
Table 2-14
Speaker
Connector
Pin Definitions
(JF1)
Pin
N u m b e r
2 8
3 0
3 2
3 4
Definition
P o w e r
N C
N C
D a t a
Overheat LED (OH)
Connect an LED to the OH connec-
tion on pin 26 of JF1 to provide
a d v a n c e d w a r n i n g o f c h a s s i s
overheating. Refer to Table 2-13
for pin definitions and Figure 2-5
for pin locations.
Pin
N u m b e r
2 6
Definition
OH Input
Table 2-13
Overheat LED (OH)
Pin Definitions (JF1)
Summary of Contents for SUPER S2QE6
Page 1: ...SUPER S2QR6 SUPER S2QE6 USER SMANUAL 1 0 SUPER...
Page 4: ...Notes SUPER S2QR6 S2QE6 User s Manual iv...
Page 8: ...SUPER S2QR6 S2QE6 User s Manual viii Notes...
Page 11: ...Chapter 1 Introduction 1 3 Introduction Notes...
Page 12: ...SUPER S2QR6 S2QE6 User s Manual 1 4 Introduction SUPER S2QR6 Figure 1 1 SUPER S2QR6 Image...
Page 13: ...Chapter 1 Introduction 1 5 Introduction SUPER S2QE6 Figure 1 2 SUPER S2QE6 Image...
Page 28: ...SUPER S2QR6 S2QE6 User s Manual 1 20 Introduction Notes...
Page 82: ...SUPER S2QR6 S2QE6 User s Manual A 4 APPENDIX A Notes...
Page 92: ...SUPER S2QR6 S2QE6 User s Manual B 10 APPENDIX B Notes...