102
To finish CUT NEEDLE setting,
press key.
CUTTING NEEDLE SET
1 => USE, 0 => NO
NO. 1 5 9
[100001000000]
FRAME ORIGIN: This function locates the original starting point of the frame. This allows the
embroidery to resume from its exact position in case of power failure.
FRAME LIMIT: Since there is no mechanical LIMIT SWITCH, the LIMIT must be set in the software.
When two points are input the LIMIT is set (see illustration below).
If you want to set the machine so that an error code to warn when the LIMIT is exceeded, go to DATA
SETUP, EMB FUNCTION, FRAME LIMIT and select YES.
LESSON: Set as P 1 X= 100, P 1 Y= 500, P 2 X-1500 and P 2 Y+-500
(P1X, P1Y)
(P2X, P2Y)
Press after placing the
cursor at “3. FRAME LIMIT
SET”.
FRAME LIMIT SET
PRESS SET KEY