background image

13

P04

Parameter 4 is the session delay. The session delay allows  a programmable amount of time at the
beginning of a session to get ready for the tanning session. The tanning session time shown on the timer
flashes during the session delay.  

The unit comes with no session delay preprogrammed.

To Change Parameter 4, Session Delay

When parameter 04 is shown, the display will read 0.0 for no session delay

.  To c

hange the session dela

y,

do the following:
Press

 “Reset”

 once then release it, the display will begin to flash. Now pres

s "up or "down"

 to reach the

desired setting. Time is displayed from 0.0 to 10.0, with the decimal representing tenths

 

of a minute.

Example: 2.5 equals 2 minutes, 30 seconds

.  After reaching the desired setting, press 

 

“Reset”

  once

and release it. Session delay is now set.

Now press

 "up"

 to reach 

Parameter 5 (P05), the Station Address function.

P05

Parameter 5 is the st ation address. The station address allows the t anning unit to be identified for
interface with the CCS series controllers, the Intellitan Single Station Console, or the Intellitan Protocol
Interface  (IPI) for your computer system. 

The unit comes with a s

ta

tion address of zero (0)

preprogrammed, if you have multiple units each must be uniquely addressed.

To Change Parameter 5, S

t

ation Address

When parameter 05 is shown, the display will read 0000 for 

stati

on address zero. To change the station

address, do the following:

Press 

“Reset”

  once and release it, the display will begin to flash. Now press

 "up" or "down"  

to reach 

the

desired 

address setting. Once the desired setting is reached press  

“Reset”

  once and release it. The 

station 

address is now set.

Now press

 "up"

 to reach 

Parameter 6 (P06), the

 

Lamp-Hour Accumulation on

 

Current Lamp Bank

function.

P06

Parameter 6 is the lamp hour accumulation counter.  The lamp hour accumulation counter keeps track of
the number of hours on the current lamp bank. This is a resettable parameter that should be reset to 0
when the lamps are changed.  When current lamp hour accumulation reaches 0000, a beep will chime
each time the unit is turned on, indicating that a lamp change is necessary

.  Chime will not sound if it has

been turned off through parameter 2. Parameter 6 is only edi

tab

le at password level 1.

When parameter 06 is shown, the display will read from 0000 to 9999. 

 To 

clear the lamp hour accumulator,

do the following:

To Clear Parameter 6, Lamp Hour Accumulation

Press 

“Reset”

  once and release, the display will begin to flash. Now press and hold 

until 0000 is

displayed.  When the display reads  0000 pres

"Re

set”

  once and release.  Lamp hour accumulation is

now cleared.

Now press

 "up" 

once and release it to reach 

Parameter 7 (P07), to measure A/C Voltage Phase A.

Parameter Detail

Summary of Contents for Radius 252

Page 1: ......

Page 2: ...1...

Page 3: ...RX FR 78 T12 SHRX 2 TO OBTAIN THE RECOMMENDED EXPOSURE POSITION OFA MINIMUM USE DISTANCE OF 6 152 4 MM MEASURED WITHA STANDARD RULER STAND UPRIGHT ON DECAL IN FLOOR OF UNIT THE USE OF ANY OTHER POSITI...

Page 4: ...tanning system while in use and advises using protective eyewear while taking a tanning session One pair of goggles is provided with each sunbed sold WARNING If you have been diagnosed by a physician...

Page 5: ...SHRX 2 B When Ordering lamps include model number and serial number Disconnect unit from power To remove acrylic from Panel D Door Panel locate the six 6 1 4 turn fasteners on the acrylic retainer st...

Page 6: ...is individual s system rarely burn tans easily and substantially R ecommended Exposure Schedule WEEK 1 1 ST 3RD TREATMENTS 2 MIN 2 MIN 2 MIN 2 MIN WEEK 2 4TH 6TH TREATMENTS 5 MIN 5 MIN 7 MIN 7 MIN WEE...

Page 7: ...panel B to base with the two 2 attachment latches by placing the latch into slot in booth panel Press downward on latch paddle latch should snap into place securing panel B to base See Illustration 3...

Page 8: ...ing procedure See Illustration 5 Illustration 5 Step 6 Remove Panel D from box marked PLD and stand panel upright into position Place washer over both top and bottom hinge pins Align hinge pins in doo...

Page 9: ...over from box and connenct the three 3 4 conductor phone cables from Panel A to timer jack plate in plastic top cover Secure top cover to top of unit using four 4 1 4 20 X 3 4 bolts See Illustration 8...

Page 10: ...the relay are improperly installed on the wrong terminals certain lamps in the tanning unit will not illuminate Refer to Schematic page 24 for more details Step 17 Contact a local licensed electrician...

Page 11: ...isplay will stop flashing and the session time will begin to count down At one 1 minute before the start of the tanning session an audible beep will sound if programmed in P02 Atthirty 30 seconds befo...

Page 12: ...he desired function Password 0010 ten must be entered to view parameters and 0102 one hundred and two to edit parameters After entering the password press the Reset button The display will stop flashi...

Page 13: ...ntain proper cooling The fan delay cannot be turned off When parameter 03 is shown the display will read 1 0 representing one minute To change the fan delay do the following To Change Parameter 3 Fan...

Page 14: ...Parameter 5 StationAddress When parameter 05 is shown the display will read 0000 for station address zero To change the station address do the following Press Reset once and release it the display wil...

Page 15: ...r the previous session or current session if the unit is energized The reading is immediately displayed Now press up and release it to reach Parameter 11 P11 the measurement of the unit s Operating Te...

Page 16: ...00 00 Now press up once and release it to reach Parameter 16 P16 the Econometer P16 Parameter 16 is the Econometer The Econometer measures the electrical cost to power unit for previous session or th...

Page 17: ...ing unit off and back on The Continuous Countdown Mode is now enabled To disable this function change parameter 24 back to 0000 Now press up once and release it to reach Parameter 25 P25 Keylock Confi...

Page 18: ...Protocol Option The default is 0001 for Intellitan Protocol The timer protocol option allows the salon owner to change timer network protocols from the Intellitan Network to theT Max1 protocol for use...

Page 19: ...18 Wiring Diagram...

Page 20: ...19 Relay Diagram...

Page 21: ...20 Relay Panel A...

Page 22: ...21 Relay Panel B...

Page 23: ...22 Relay Panel C...

Page 24: ...23 Relay Terminal Block...

Page 25: ...24 Ballast Tray Connection...

Page 26: ...25 Ballast Tray A1 B1 and C1...

Page 27: ...26 Ballast Tray A2 and C2...

Page 28: ...27 Ballast Tray B2...

Page 29: ...28 Bed Cords...

Page 30: ...29 Door Harness...

Page 31: ...30 3 Phase Connection...

Page 32: ...le Phase Connection NOTE This unit is factory pre wired for three phase operation During conversion to single phase operation you must replace the incoming power wires to 4 gage THHN 90 degrees or equ...

Page 33: ...iagram and correct as required SOLUTION 1 Remove lamp inspect contact on lamp and reinstall lamp securely into lampholder 2 Replace lamp Refer to Instruction Manual for correct lamp General Troublesho...

Page 34: ...0 h 3 Months 500 h 6 Months 2500 h 1 Year 5000 h 5 Years 10000 h 10 Years 1 Bolts fasteners bushings of the door hinge mechanism X Inspect and replace as necessary Bolts fasteners bushings of the door...

Page 35: ...mpletes and returns the enclosed warranty card within 10 days after purchase to insure valid registration and coverage for potential claims If the warranty card is not registered proof of purchase fro...

Page 36: ...placement acrylic JK Products assumes no liability for the cost of removing defective sheets or installing replacement sheets nor for damage to persons or property To make a claim contact an authorize...

Page 37: ...arranty and nonwarranty needs of their customers Therefore in order for you to properly file a Warranty Claim you must locate the name and phone number of the dealer distributor through whom you purch...

Page 38: ...cerning this claim NOTE If part returned to JK Products proves to be operational and not defective or if product code numbers on part do not correspond with individual unit date on file with JK Produc...

Page 39: ......

Page 40: ...said p arty to direct responsibility and liabilities for any and all consequences resulting from such action Furthermore such actions will void all warranties and may relieve 3URGXFWV of any liabiliti...

Reviews:

Related manuals for Radius 252