12
P02
Parameter 2 is the chime mechanism that provides an audible ‘beep’ sound when the keys are depressed
and to indicate the various operations occurring. The audible beep can be turned on or turned of
f.
The u
nit
comes with the chime mechanism turned on to provide an audible beep. When
parameter 02 is
shown, the display will read 0001.
To maintain the chime mechanism, press the
s
now and go to
P03.
To
silence it, do the following:
To Change Parameter 2, Alarm On/Off
Press
“Reset”
once then release it. The display will begin to flash. Press
s
and hold it down, scrolling
down to 0000. Now
“Reset”
press once again. The chime is now deactivated. To reactivate the chime,
change parameter 02 back to 0001 using the same instructions provided above.
Now press
s
to reach
Parameter 3 (P03), the Fan Delay or Post Session Cooling
P03
Parameter 3 is the fan delay. The fan delay maintains proper cooling of the
ta
nning unit by continuing to
provide power to the cooling fans for a programmable amount of time after the tanning session has
completed.
The unit comes with the fan delay preprogrammed at one (1) minute.
Certain salon
conditions may warrant a higher fan delay to main
tai
n proper cooling. The fan delay cannot be turned o
ff.
When parameter 03 is shown, the display will read 1.0 representing one minute.
To
change the fan dela
y,
do the following:
To Change Parameter 3, Fan Delay
Press
“Reset”
once then release it, the display will begin to flash. Press either
s
or
t
to reach
desired setting. Time is displayed from 1.0 to 5.0, with decimal representing
tenths
of a minute. For
Example: 1.5 equals 1 minute, 30 seconds.
After setting the fan delay press
“Reset”
once then
release it. The fan delay is now set.
NOTE: Fan Delay
The duration of the fan delay is not displayed on the timer while the fan delay is counting dow
n. Tim
e is,
however, displayed on the CCS-1 or the other control device during the fan delay to indicate how long the
fan delay has remaining. After a tanning session has expired, the ( _ _:_ _ ) will flash and the numeric
digits display will blink (off). If the Clean Room feature is on then along with the flashing colon (:) dashes
will appear in the display ( - - : - - ). When displayed on the CCS-1 or other control device the duration of
the fan delay counts down in three second decrements.
Note:
When the Intellitan Plus timer is on a network no new time can be placed on the timer until af
ter t
he
fan delay has expired. The fan delay cannot be turned off.
Now press
"up"
to reach
Parameter 4 (P04), the Session Delay function.
Parameter Detail
Summary of Contents for Radius 252
Page 1: ......
Page 2: ...1...
Page 19: ...18 Wiring Diagram...
Page 20: ...19 Relay Diagram...
Page 21: ...20 Relay Panel A...
Page 22: ...21 Relay Panel B...
Page 23: ...22 Relay Panel C...
Page 24: ...23 Relay Terminal Block...
Page 25: ...24 Ballast Tray Connection...
Page 26: ...25 Ballast Tray A1 B1 and C1...
Page 27: ...26 Ballast Tray A2 and C2...
Page 28: ...27 Ballast Tray B2...
Page 29: ...28 Bed Cords...
Page 30: ...29 Door Harness...
Page 31: ...30 3 Phase Connection...
Page 39: ......