9
Step 15
Attach ballast access covers with #6 x 3/8 philips
screws and snap caps.
(
See
Illustration 11
)
Step 16
There are two terminal blocks located on the ballast tray
installed in each panel. Each panel has a relay with four
power wires (2 Black & 2 Red) with quick-slide connectors
that are to be connected to the mentioned terminal blocks
at the time of installation. Install the wires on the terminal
block as shown with the corresponding colors. If the
wires from the relay are improperly installed on the wrong
terminals, certain lamps in the tanning unit will not illuminate.
(Refer to Schematic page 24, for more details.)
Step 17
Contact a local licensed electrician to connect electrical supply to unit. Your tanning booth requires a
120V/225V three phase, 50 amp service or 120V/225V single phase 80 amp 4 wire service. Use of a voltage
source below 215VAC or above 230VAC may prevent proper operation of the booth and could cause damage
and void the warranty.
NOTE: This unit is factory pre-wired for three phase operation. See page 31 for single phase
conversion instructions and wire gage.
Assembly Instructions
Illustration 11
Summary of Contents for Radius 252
Page 1: ......
Page 2: ...1...
Page 19: ...18 Wiring Diagram...
Page 20: ...19 Relay Diagram...
Page 21: ...20 Relay Panel A...
Page 22: ...21 Relay Panel B...
Page 23: ...22 Relay Panel C...
Page 24: ...23 Relay Terminal Block...
Page 25: ...24 Ballast Tray Connection...
Page 26: ...25 Ballast Tray A1 B1 and C1...
Page 27: ...26 Ballast Tray A2 and C2...
Page 28: ...27 Ballast Tray B2...
Page 29: ...28 Bed Cords...
Page 30: ...29 Door Harness...
Page 31: ...30 3 Phase Connection...
Page 39: ......