Page 8
Induction Range (IR) Series
Induction Range (IR) Series
Electronics
2-8
#827176 - Revision A.2 - September, 2017
Display States in Operational Mode
ALL OFF
is turned on.
•
SIM/MLT
,
“…”
,
HI
,
BOOST
, and
BRIDGE/BRG
are on if they have been activated.
•
All other displays for the active control zone are off.
•
All other displays in Idle Mode are off.
•
Power level indicators (
SIM/MLT
or
“…”
) less than the power level selected are on.
•
Power levels greater than selected power level are off.
•
Adjusting the power level on any bridged coil assembly changes all power levels and displays in the bridge.
•
ALL OFF
De-energizes the entire cooktop at any time.
•
Does not turn off the
TIMER
.
•
Error Mode
Note:
For error codes see Section 4 - Troubleshooting.
System logs initial generation of an error into memory for later inspection.
•
Up to 8 errors can be logged in memory.
•
All detected errors logged regardless of priority.
•
Errors may be canceled by the user or be self-correcting.
•
Specific zones are not recorded in diagnostic mode if a cooking zone specific error is logged.
•
If there are more than 8 error codes the error log displays the most recent and discards the oldest error.
•
Errors are displayed using error codes.
•
Error codes are also used in Diagnostic Mode.
•
When an error is displayed it is accompanied by the Failure beep.
•
Active error is one that is currently being displayed, other errors can be debounced and logged while another
•
error is active.
Some errors are only displayed when a pad in the affected control zone is touched.
•
Showroom Mode
Notes and Restrictions in Showroom Mode
Full user functionality with no power being supplied to the coil assemblies.
•
Available on 120 VAC (without transformer) or 240 VAC power.
•
Connecting the unit to 120 VAC causes error E6. This is normal. Proceed with the steps to place unit in
•
Showroom mode.
If unit is placed into Showroom mode when the heat sink is 113° F or higher, the generator fan will run.
•
Hot surface indicator is not visible.
•
Entering Showroom Mode
Engaged from Diagnostic Mode. See Diagnostic Mode.
Exiting Showroom Mode
Disengaged from Diagnostic Mode. See Diagnostic Mode.
Operation of Showroom Mode
No power is supplied to the coil assemblies.
•
Control operates as if power was supplied to the coil assemblies.
•
All visual and audible feedback functions as if in Operational Mode, except pot detection.
•
When cooktop is in Showroom Mode the LOCK LED is visible.
•
SH
is displayed at all times in the 2-digit display, unless the timer is activated.
•
SH
is displayed in 2-digit display 5 minutes after last Timer pad touch.
•
On loss of power cooktop returns to Showroom mode.
•