Page 5
Electronics
Induction Range (IR) Series
Induction Range (IR) Series
2-5
#827176 - Revision A.2 - September, 2017
Modes
Power Up Mode
All LED indicators are on for two seconds.
•
After LED power up sequence the annunciator sounds the Acceptance beep.
•
During the Acceptance beep the cooktop enters Lock Mode.
•
LOCK
display is on.
•
Lock Mode
No pad can function except for the
LOCK
pad or the pads associated with entering Diagnostic Mode.
Entering Lock Mode
Engages after ten continuous minutes of Idle Mode.
•
After power up sequence.
•
Touch and hold
LOCK
pad for 3 seconds when in Idle Mode.
•
Annunciator sounds Acceptance beep when Lock Mode is entered.
•
LOCK
LED is visible.
•
Annunciator sounds Failure beep if any control zone is active when trying to enter Lock Mode.
•
Exiting Lock Mode
Touch and hold the
LOCK
pad for 3 seconds.
•
If
LOCK
pad is held for more than 10 seconds cooktop relocks.
•
Annunciator sounds Acceptance beep to indicate Lock Mode has been exited.
•
LOCK
LED turns off and control zones enter Idle Mode.
•
Valid key presses in Lock Mode
LOCK
pad for exiting Lock Mode.
•
Touch and hold
“+”
and
“-”
pads for 5 seconds to enter Diagnostic Mode.
•
Display states in Lock Mode
LOCK
display is on.
•
All other displays are off.
•
Idle Mode
Cooktop is unlocked and control zones are inactive.
Valid key presses in Idle Mode
LOCK
– Touch and hold
LOCK
pad to enter Lock Mode.
•
ON/OFF
– Touch any control zone
ON/OFF
pad places that control zone in Wake-Up Mode.
•
TIMER
– Touch
TIMER
pad activates the Timer.
•
Display states in Idle Mode:
All displays are off.