Diagnostic Mode
Used to test the cooktop systems, view stored error codes, view real-time readings from system sensors, and to
enter/exit Showroom mode.
Entering Diagnostic Mode
Must be entered from Lock Mode.
•
Touch and hold the
“+”
pad and
“-”
pad for 5 seconds.
•
After 5 seconds enters LED test, alerting the user to remove their fingers.
•
If another key pad sensor detects a signal, Diagnostic Mode does not engage.
•
If either the
“+”
or
“-”
pad is not released after 7 seconds, Diagnostic Mode does not engage.
•
Power to all coil assemblies is disabled.
•
After 60 seconds if no input is detected the control returns to Lock Mode.
•
ALL OFF
pad exits Diagnostic Mode and the control returns to Lock Mode.
•
There are no audible signals.
•
To step through the various tests touch the
“+”
and
“-”
pads.
•
Rear left
“…”
display advances one LED for each test to identify which test is being performed.
•
Diagnostic Mode Procedures
LED Test
All LED indicators for all control zones are on.
LOCK
LED, all segments of the Timer display,
HOT
display
•
and all
BOOST
LEDs are on.
Front left control zone
SIM/MLT
,
“…”
or
HI
pads cycles LEDs to on, dim, or off.
•
One
“.”
displayed on the left rear control zone indicates LED test is running.
•
“+”
pad engages Unit Reconfiguration.
•
Unit Reconfiguration and Unit Derating
b1. Unit Reconfiguration - software version below version V.10
Touch
“+”
pad during the LED test.
•
Two
“.”
are displayed on left rear control zone.
•
CF
is displayed in the 2-digit display.
•
Only one
“.”
is displayed in the front left control zone.
•
Press and hold
“+”
and
“-”
pads together for 3 seconds activates the unit reconfiguration.
•
Acceptance beep is sounded after the requisite press-and-hold and the cooktop resets.
•
“-”
pad engages LED Test.
•
“+”
pad engages Control Temperature Readout.
•
b2. Fully Rated to Derated and Unit Reconfiguration - software version V.10 or higher
Touch
“+”
pad during the LED test.
•
Two
“.”
are displayed on left rear control zone.
•
CF
is displayed in the 2-digit display.
•
Front left control zone
SIM/MLT
, or
HI
pads cycles between “fully rated,” or “derated” mode.
•
If first
“.”
is brighter then the second
“.”
on the front left control zone, unit is in “fully rated” mode.
•
If second
“.”
is brighter then the first
“.”
on the front left control zone, unit is in “derated” mode.
•
Press and hold
“+”
and
“-”
pads together for 3 seconds activates the unit reconfiguration, and sets the
•
unit in the “fully rated” or “derated” mode.
Acceptance beep is sounded after the requisite press-and-hold and the cooktop resets.
•
“-”
pad engages LED Test.
•
“+”
pad engages Control Temperature Readout.
•
NOTES:
Reconfiguring the unit resets the communication between the generator and control board software.
•
Reconfiguring the unit is recommended to be performed for any electronic communications error and after
replacing a generator or control board.
The power rating of the unit does not have to be changed to perform unit reconfiguration.
•
Left rear
“.”
remains at two and CF is displayed in the 2-digit display during the unit reconfiguration.
•
After replacing a generator the
LOCK
light does not illuminate. The unit is locked.
•