Attaching the
brake to the ad-
jacent structure
NOTICE
Risk of damage due to the incorrect tight-
ening torque
An incorrect tightening torque can lead to damage that
may even include components breaking.
► Observe the tightening torque.
1. Tightly screw the brake to the adjacent struc-
ture (100) with the fixing screws (12) and discs (14).
Use liquid screw locking agent if necessary, see
section 4.3.
SKB-0404
12
14
100
Fig. 11
6.4.2
Mount the pressurised medium line
Observe the instructions regarding the pressurised medium supply, see section 2.3.1 and section 5.3.1.
Assembly of the
leak line (if provi-
ded)
1. If a leak line connection (L) is provided, remove the
drain screw (13).
2. Mount the leak line (add-on component of the cus-
tomer) at the leak line connection (L).
SKB-0405
L
13
Fig. 12
Assembly of the
pressure line
NOTICE
Damage to the brake due to contaminated
pressurised medium
When the pressurised medium system is flushed by the
customer, this may cause contamination of the pressur-
ised medium. This must not enter the brake.
► The pressurised medium system must be flushed by
the customer before being connected to the brake.
1. Flush the pressure line (add-on component of the
customer).
2. Connect the pressure line to the pressure line con-
nection (D).
SKB-0406
D
Fig. 13
28
Mounting instructions Pressure-operated spring-actuated multi-disc brake KMB-ZM, KLB-ZM • No. 777-00001 D • 10/2017