5.4
Optional equipment
5.4.1
Switching status monitoring
SKB-0153
26
3
30
29
28
1
27
C
x
DD 592062 / Fig. 8
C
LED function display
27
Proximity transducer with nut
X
Distance dimension
28
Angle
1
Coil body
29
Screw
3
Armature plate
30
Washer
26
Control disc
On request the clutch can be supplied with switching status monitoring, to determine and assess the position of
the armature plate (3).
This eliminates meshing problems such as head-on-head positions, ensuring safe engagement of the coupling.
The armature plate is additionally equipped with a control disc (26) for this purpose.
A proximity transducer (27) is attached to the coil body (1) with the help of a bracket (28) in such a way that it
can be fixed to the control disc in a specific position.
The required distance dimension (X) for this can be obtained from the dimensional drawing, see section 4.3.
When moving the control disc closer to the proximity transducer, the contact will close once the switching point
has been reached.
NOTE
Setting instructions for the inductive proximity transducer can be requested from Stromag’s Customer
Care department (doc. 576-00433).
A three-conductor line is required to connect the proximity transducer (27).
25
Mounting instructions Electromagnetic tooth clutch EZB • No. 590-00000 E • 10/2017
Summary of Contents for EZB
Page 2: ......
Page 6: ...VI Montageanleitung Elektromagnet Zahnkupplung EZB Nr 590 00000 E 10 2017...
Page 45: ...39 Montageanleitung Elektromagnet Zahnkupplung EZB Nr 590 00000 E 10 2017...
Page 48: ......
Page 52: ...VI Mounting instructions Electromagnetic tooth clutch EZB No 590 00000 E 10 2017...
Page 91: ...39 Mounting instructions Electromagnetic tooth clutch EZB No 590 00000 E 10 2017...