![Stober 56690 Manual Download Page 92](http://html.mh-extra.com/html/stober/56690/56690_manual_1381233092.webp)
9 | Connection
STOBER
92
05/2019 | ID 442790.01
9.4.16
X101: BE1 – BE4
The binary inputs 1 to 4 are available on terminal X101.
X101 for binary signals
For evaluating binary signals at X101, note the specification for the binary inputs in the technical data of the drive
controller, see the chapter
.
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE1
Binary inputs
2
BE2
3
BE3
4
BE4
5
DGND
Reference ground; not bridged with X103, pin 5
Tab. 89: X101 connection description for binary signals
X101 for encoders
If you would like to use X101 as an encoder connection, note the technical data of the evaluable encoders at X101; see the
chapter
Single-ended HTL incremental encoders
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE1
—
2
BE2
N channel
3
BE3
A channel
4
BE4
B channel
5
DGND
Reference ground; not bridged with X103, pin 5
Tab. 90: X101 connection description for single-ended HTL incremental signals, axis A
Single-ended HTL pulse train
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE1
—
2
BE2
—
3
BE3
Frequency
4
BE4
Direction
5
DGND
Reference ground; not bridged with X103, pin 5
Tab. 91: X101 connection description for single-ended HTL pulse/direction signals, axis A
Connecting wiring
For connecting wiring, observe the terminal specifications in the chapter
Cable requirements
Feature
All sizes
Max. cable length
30 m
Tab. 92: Cable length [m]