Message text (English)/
Error code
Comment
OVERHEATING
A5022
Traction motor(s) is/are too hot.
1. phase: regulation of acceleration and speed.
2. phase: limitation of the phase current in the converter
(emergency driving function is retained).
The error automatically disappears as soon as the tempera-
ture is below the limit.
If the error occurs more frequently, notify your authorised
service centre.
OVERHEATING
A5364
Pump converter is too hot.
Notify the authorised service centre.
ACCELERATOR
A3002
A3003
A3004
A3005
A3006
A3007
A3505
Sensor fault, truck cannot be driven.
Notify the authorised service centre.
ACCELERATOR
A3008
Accelerator voltages (for dual pedal) do not match; truck
cannot be driven.
Notify the authorised service centre.
ACCELERATOR
A3811
Accelerator configuration is invalid. The truck cannot be driv-
en.
Notify the authorised service centre.
BRAKE SENSOR
A3016
A3017
Sensor fault; truck can only be driven at emergency mode
speed.
Notify the authorised service centre.
CONFIGURATION
A2111
A3801
A3812
Parameterisation error; drive unit and hydraulic drive not
functioning.
Notify the authorised service centre.
SEAT SWITCH
A302
Seat switch has not been operated for approx. 8 hours.
Truck can possibly still be driven at a reduced speed and
with reduced lifting capacity.
Stand up briefly and then sit down again.
If this does not resolve the problem, contact your authorised
service centre.
STEERING
A3215
A3216
A3570
Sensor fault; truck can be driven at emergency mode speed.
Notify the authorised service centre.
DIRECTION SWITCH
A3020
Switch error; no or limited drive unit function.
Notify the authorised service centre.
Operating
4
Display messages
257
56358042501 EN - - 11
Summary of Contents for RX60-60
Page 2: ......
Page 13: ...1 Foreword ...
Page 20: ...Overview Foreword 1 Your truck 8 56358042501 EN 11 ...
Page 41: ...2 Safety ...
Page 70: ...Safety 2 Emissions 58 56358042501 EN 11 ...
Page 71: ...3 Overviews ...
Page 83: ...4 Operating ...
Page 336: ...Operating 4 Decommissioning 324 56358042501 EN 11 ...
Page 337: ...5 Maintenance ...
Page 344: ...Maintenance 5 General maintenance information 332 56358042501 EN 11 ...
Page 381: ...6 1000 hour maintenance annual mainte nance ...
Page 385: ...7 Technical data ...
Page 398: ...Technical data 7 Fuse assignment 386 56358042501 EN 11 ...
Page 407: ......
Page 408: ...STILL GmbH 56358042501 EN 11 ...