Maintenance
6
Servicing
Checking the condition and safety of
the electrical connections and cables
DANGER
Danger of death from electric shock!
– Never wear watches or jewellery when working
on a battery.
– Never touch non-insulated cables.
– Never touch damaged plugs.
– ALWAYS use an insulated tool.
– Always wear a proper personal protection suit.
– Switch off the key switch.
– Disconnect the battery.
– Check the tightness of the connections.
– Ensure that the battery cables are undam-
aged and well insulated.
– Check the safety of the cable connections
of the electric motor.
– Ensure that all motor cables are undam-
aged and well insulated.
– Remove all signs of corrosion and replace
any damaged cables.
NOTE
Corroded connections and damaged cables
cause voltage drops and overheating which
can lead to operating problems.