5
Operation
Battery
Unplug the battery charger from the battery
connector.
– Close the cover plate (3) of the battery
connector.
Equalising charge to prevent a deep
discharge of the battery
Lead-acid batteries must be charged at least
once per week for equalisation purposes. This
is to ensure that all battery cells are evenly
charged. This prevents a deep discharge of
the battery and extends its life span.
NOTE
Dependent on the battery charger used, the
equalising charge may not begin until 24 hours
have elapsed. A period when no shifts are
running, such as the weekend, is therefore
ideal for performing the equalising charge.
– Observe the information in the operating
instructions of the battery charger regarding
how to perform an equalising charge.
Starting the equalising charge
– Charge the battery.
– After charging, leave the battery in the
battery charger.
The battery charger remains switched on.
Depending on the battery charger used, the
equalising charge starts after between 6 and
24 hours. The equalising charge takes up to
2 hours.
98
172780 EN - 06/2017
Summary of Contents for R 07-25
Page 2: ......
Page 4: ......
Page 11: ...1 Foreword ...
Page 18: ...1 Foreword Environmental considerations 8 172780 EN 06 2017 ...
Page 19: ...2 Introduction ...
Page 28: ...2 Introduction Residual risk 18 172780 EN 06 2017 ...
Page 29: ...3 Safety ...
Page 45: ...4 Overviews ...
Page 59: ...5 Operation ...
Page 163: ...6 Maintenance ...
Page 212: ...6 Maintenance Maintenance intervals 202 172780 EN 06 2017 ...
Page 217: ...7 Technical data ...
Page 244: ......
Page 245: ......
Page 246: ...STILL GmbH 172780 EN 06 2017 ...