35
Pipe dimensions
of the connecting pipe
Recommended pipe dimension of the connecting pipe
Length of pipe F + BF
Number of collectors
up to 10 m
from 10 m
to 15 m
from 15 m
to 20 m
2 coll. - 132 L/h
12 x1
15 x 1
15 x 1
3 coll. - 198 L/h
15 x 1
15 x 1
15 x 1
4 coll. - 264 L/h
15 x 1
18 x 1
18 x 1
5 coll. - 330 L/h
18 x 1
18 x 1
18 x 1
6 coll. - 396 L/h
18 x 1
18 x 1
22 x 1
7 coll. - 462 L/h
22 x 1
22 x 1
22 x 1
8 coll. - 528 L/h
22 x 1
22 x 1
22 x 1
9 coll. - 594 L/h
22 x 1
22 x 1
22 x 1
10 coll. - 660 L/h
22 x 1
22 x 1
22 x 1
11 coll. - 726 L/h
22 x 1
22 x 1
28 x 1,5
12 coll. - 792 L/h
22 x 1
22 x 1
28 x 1,5
13 coll. - 858 L/h
22 x 1
28 x 1,5
28 x 1,5
14 coll. - 924 L/h
22 x 1
28 x 1,5
28 x 1,5
15 coll. - 990 L/h
22 x 1
28 x 1,5
28 x 1,5
Length of pipe F + BF
Number of collectors
from 20 m
to 25 m
from 25 m
to 30 m
from 30 m
to 35 m
from 35 m
to 40 m
2 coll. - 132 L/h
15 x 1
15 x 1
15 x 1
15 x 1
3 coll. - 198 L/h
18 x 1
18 x 1
18 x 1
18 x 1
4 coll. - 264 L/h
18 x 1
18 x 1
18 x 1
22 x 1
5 coll. - 330 L/h
22 x 1
22 x 1
22 x 1
22 x 1
6 coll. - 396 L/h
22 x 1
22 x 1
22 x 1
22 x 1
7 coll. - 462 L/h
22 x 1
22 x 1
22 x 1
28 x 1,5
8 coll. - 528 L/h
22 x 1
22 x 1
28 x 1,5
28 x 1,5
9 coll. - 594 L/h
22 x 1
28 x 1,5
28 x 1,5
28 x 1,5
10 coll. - 660 L/h
28 x 1,5
28 x 1,5
28 x 1,5
28 x 1,5
11 coll. - 726 L/h
28 x 1,5
28 x 1,5
28 x 1,5
28 x 1,5
12 coll. - 792 L/h
28 x 1,5
28 x 1,5
28 x 1,5
28 x 1,5
13 coll. - 858 L/h
28 x 1,5
28 x 1,5
28 x 1,5
28 x 1,5
14 coll. - 924 L/h
28 x 1,5
28 x 1,5
28 x 1,5
35 x 1,5
15 coll. - 990 L/h
28 x 1,5
28 x 1,5
35 x 1,5
35 x 1,5