18
Assembly roof-tile clamps
Completely tiled roof.
When mounting the field in regions with high snow load zone of 2
kN/m², it is necessary to place the roof hooks in the rafter area.
Removal of the tiles after previous determination of the placement
of the roof-tile clamps (see page 10 “Spacing multi-row collector
fields“).
Fixation of the lower lath 24x80x600 mm with two screws 5x60 mm.
If the lath is placed near the counter lath, the lath 24x80x600 mm
must not be applied.
1410002 Roof-tile clamp V2 without lead
The lower roof-tile must be remounted.
Before covering the lower roof-tile must be coarsly ground.
To avoid breaking of the tile the roof-tile clamp must not rest on the
tile.
The lower tile must be coarsly ground so that the roof-tile clamp
rests in the middle of the tile.
Mount the tile clamp support 80x270x30 mm and fix it with two
screws 5x60 mm.