General
61/65
Z001138-1_2013-02-01
H 3 Testing of torque wrenches
The torque wrenches are subject to regular tests of the set values. By doing so, the
tripping value of signalling torque wrenches and the scale accuracy of measuring torque
wrenches are tested.
H 4 Non-destructive material testing
For the detection of surface cracks, the non-destructive test according to colour
penetration test procedure is recommended.
The work piece is sprayed or coated with a penetration agent, and after drying a developer
is applied.
After a development time of appr. 10 minutes, defects on the work piece appear as dots or
lines.
H 5 Use of adhesive and sealing materials
In the workshop manual adhesive and sealing materials are specified for the repair of
engines and aggregates, which are used at operating temperatures of up to 150° C and
agents such as water, coolants and hydraulic fluids, engine and gear oils as well as fuels.
Solvent-free sealing materials
The hardening takes places without loss of volume, so that a retightening of screw
connections is not necessary.
Anaerobic sealing materials
These are used for securing, fixing and sealing, and only harden under exclusion of air.
Solvent containing sealing materials
Due to their contents of volatile parts a loss of volume occurs during hardening. During
repair, the hardening time is taken into consideration. If such sealing materials are used,
special reference is made in the description of the workshop manual.
H 6 Solvent-free sealing materials
Silicon sealing materials
They consist of silicon and filling materials and are free of solvents.
The product is applied to the cleaned sealing surface from the tube or cartridge in form of
a string. Sealing material residues are removed with cleaning agent.
Silicon sealing material is to be stored below 30° C.
Anaerobic sealing materials
They consist of a single component epoxy in liquid form. The product is applied as a liquid
to the components and remains liquid, as long as it is in contact with ambient air (oxygen).
Only when the parts are assembled, chemical reaction starts due to exclusion of air
(oxygen) and metal contact, i.e. transformation of liquid state into an epoxy built up by
molecular chains. Any residues remaining after assembly and/or are pressed out of the
connection remain liquid and may be removed easily.
Summary of Contents for Marine Engine 2012 Series
Page 35: ...General 35 65 Z001138 1_2013 02 01 Trouble Indication ...
Page 36: ...General Preliminary Service Manual MARINE 2012 Z001138 1_2013 02 01 36 65 ...
Page 51: ...General 51 65 Z001138 1_2013 02 01 G Notes on safety ...
Page 69: ...Engine Z001138 1_2013 02 01 4 87 Kapitel MOUNT BRACKET COVER T BELT GASKET SET ...
Page 154: ...Fuel System Z001138 1_2013 02 01 2 51 ...
Page 159: ...Fuel System 7 51 Z001138 1_2013 02 01 03 00 03 Unit injector ...
Page 190: ...Fuel System Z001138 1_2013 02 01 38 51 Schema Injection Timing Device ITD ...
Page 211: ...Cooling System 5 21 Z001138 1_2013 02 01 ...
Page 231: ...Electrical System Z001138 1_2013 02 01 4 47 ...
Page 235: ...Electrical System Z001138 1_2013 02 01 8 47 ...
Page 236: ...Electrical System 9 47 Z001138 1_2013 02 01 ...
Page 238: ...Electrical System 11 47 Z001138 1_2013 02 01 ...