45
MOTOR
COIL REPLACEMENT
continued
11.
With wire strippers set at 16 gauge, strip approximately 1/2" from the power cord
and on/off switch lead wires in the motor housing.
12.
Secure ground wire (with eyelet) to motor coil.
13.
Crimp the stripped lead wires to each of the new coil lead wires.
14.
Tuck wire nuts into bottom of motor cover and secure cover back in place (before
tightening, reverse cover screws to catch original threads).
15.
Apply power to motor and test.
USA and Canada 800.683.2378, International 904.641.1666.
Lead Wire
Ground
Wire
Strip Approx, 1/2"
Wire Stripper
Lead Wire
Ground Wire