32
PUMP HEAD
FIXED RATE MODEL
REMOVE PUMP HEAD & INSTALL QuickPro
®
PUMP HEAD
1.
Turn off the pump and unplug the power cord.
a.
To remove the pump head, hold the pump securely, grasp the head and turn it
clockwise until it stops.
Figure A
b.
Remove the tube housing and roller assembly together by pulling it straight out
from the pump. The shaft will remain in the pump. Discard the tube, housing
and cover. If the housing and roller assembly are difficult to remove, insert a
large, flat blade screwdriver between the pump body and the head. Gently pry
the head forward, ensuring the rivets on the pump body remain disengaged
from the tube housing.
c.
Put the new pump head onto the motor and turn it counter-clockwise until the
shaft falls into place.
Figure D
2.
Push the pump head in while turning it counter-clockwise. Line up the rivet holes on
the pump head with the rivets on the feed rate control (adjustable pump) OR motor
(fixed output pump).
Figure D
3.
Continue to push until the rivets are inside the holes.
4.
Turn the pump head counter-clockwise to secure the rivets in the rivet slots, firmly
attaching the pump head. Proceed to page 33.
PUMP HEAD REPLACEMENT
continued
www.stenner.com
A
D