38
FRC PARTS REPLACEMENT
continued
8.
Apply Aquashield
®
to the inside of the dial ring for easier turning.
9.
Place dial ring boss onto the cam’s 90° end.
10.
While keeping the 90° end in the boss and the cam in the FRC channel, in a
clockwise motion, place the dial ring onto the FRC housing and snap into place.
11.
Apply AquaShield
®
to bottom of the FRC housing before placing index plate inside.
Apply AquaShield
®
to the top of the index plate.
12.
Place the spider assembly on the index plate. The lifter tip should be positioned in
the 1/2" gap in the FRC channel.
13.
To secure mounting plate, align its arrow with the FRC housing arrow and install the
three screws.
If the dial ring does not rotate from L to 10, the FRC mounting plate is in the
wrong orientation.
The dial ring will be stiff or difficult to rotate if it lacks AquaShield
®
or the
screws are over tightened. If the screws are too loose, the dial ring can
inadvertently be turned to setting 10 by the motor.
FEED RATE CONTROL
www.stenner.com