37
1.
Remove and set aside:
•
Three screws
•
Feed rate mounting plate
•
Dial ring (observe installed cam)
•
Brass spider assembly
•
Index plate
2.
If required, remove index pin assembly by unscrewing with a 3/8" wrench
and replace.
3.
Flip worn index plate over OR install new index plate.
4.
Clean out FRC channel before installing new cam.
5.
Apply AquaShield
®
to lubricate the cam’s angled tip.
6.
To install the cam, feed the angled cam tip into the FRC channel and keep the
90º end in the up position. Place thumb over the cam to guide as it is inserted in
the channel.
7.
Continue to feed the cam in the channel until there is approximately a 1/2" gap
between the cam tip and the beginning of the channel.
FRC PARTS REPLACEMENT
FEED RATE CONTROL
USA and Canada 800.683.2378, International 904.641.1666.
Angled tip
3/8" wrench
Angled end
90º angle
Installing New Cam
90º end