17
CONDITIONS THAT REDUCE TUBE LIFE
IMPROPER TUBE HANDLING
•
Not following factory tube replacement instructions.
•
Storing tubes in high ambient temperatures or long term exposure to direct sunlight
weakens tube material.
•
Prior to installation, pre-stretching, lubricating the tube and/or roller assembly or
pinching during installation, compromises the tube material.
•
Excessive pulling of the tube fitting, during installation, can result in compromising
the material. Allow the pump to run the roller assembly in its collapsed position
for approximately one minute to relax the tube as indicated in the tube
replacement instructions.
•
Using pliers to center or secure connections can damage ferrules. The connecting nut
must be finger tightened only.
•
Using thread seal tape prevents ferrules from seating properly into tube fitting and
can cause leaks.
•
Not allowing enough slack in the suction and discharge lines so the tube fittings can
flex puts stress on the tube and fittings.
DO NOT
use thread seal tape or pliers on pump tube threads.
PUMP TUBE
USA and Canada 800.683.2378, International 904.641.1666.