25
INSTALL TUBE
continued
4.
With the cover latched, plug the pump in and turn the power on. Allow the pump to
run the roller assembly in its collapsed position for approximately one minute to
relax the tube.
Figure K
5.
Turn the pump off and unplug the power cord.
6.
Remove the tube housing cover and flip to use as a tool in the next step.
Figure L
7.
Align the center of the inverted cover with the center of the roller assembly so that
the three holes on the face of the cover align with the three knurled lugs on the
roller assembly. Position the cover feet near the bottom.
Figure M
NOTE: The roller assembly needs to be expanded so the tube is pressed against the
tube housing wall.
PUMP TUBE
TUBE REPLACEMENT
continued
USA and Canada 800.683.2378, International 904.641.1666.
K
L
M