19
At every tube change, trim approximately 1" off the end of both the suction
and discharge lines before installing new ferrules. Replace duckbill (26-100
psi applications) and ferrules with every new tube.
CONDITIONS THAT REDUCE TUBE LIFE
continued
EXCESSIVE BACK PRESSURE AT THE POINT OF INJECTION
Calcium or mineral deposits in the injection fitting section of the check valve can cause
blockage or restriction creating back pressure that exceeds the pump tube pressure rating.
Corrective Action
1.
Insert a round shank screwdriver through injection fitting into the pipe to locate or
break up accumulated deposits. If screwdriver can’t be inserted, drill the deposit
out of the injection fitting. Do not drill through the opposite pipe wall.
2.
Replace duckbill.
EXCESSIVE BACK PRESSURE AT THE POINT OF INJECTION
Insoluble sediments or particulates drawn through the suction line from the bottom of
the tank can cause blockage or restriction in the check valve duckbill. These solids and
excessive pressure can damage the pump tube.
Corrective Action
1.
Replace suction and discharge tubing and clean sediment from tank bottom.
2.
Position weighted strainer 3" from tank bottom.
3.
Replace duckbill.
PUMP TUBE
USA and Canada 800.683.2378, International 904.641.1666.
Areas that clog
Injection Check Valve
Duckbill
Clean out accumulated deposits
with a #2 phillips head screw driver
Replace duckbill