47
MOTOR
GEAR WEAR
Generally, gear failure can be caused by misalignment mainly due to the wear over the
service life of the pump.
Check for the following conditions that can contribute to the phenolic gear stripping.
•
Water or chemical intrusion
•
Cracked bearing bracket
•
Worn gear posts
•
Worn gear case cover
•
Rusted helical gear
•
Insufficient lubrication
Corrective Action
1.
Review the vertical installation that includes using a rain roof in outdoor
applications or wet environments.
2.
Replace gears that show visible wear or corrosion.
3.
Replace gear posts that are worn, rusted or corroded.
4.
Inspect the gear case and cover for cracks or corrosion and replace as needed.
5.
Inspect the helical gear at the end of the rotor. Buff off the rotor if rusted or
replace the rotor assembly.
6.
Lubricate with AquaShield
®
.
Apply a generous amount of AquaShield
®
to gear posts, pinions, gear rings
and the main shaft with gear after doing service in the gear case.
USA and Canada 800.683.2378, International 904.641.1666.
Phenolic Gear
Teeth missing