StecaGrid 2500/x
StecaGrid 3010/x
Maximum start voltage
600 V
Maximum input voltage
600 V
Minimum input voltage for grid-
feeding
125 V
Start input voltage
150 V
Rated input voltage
320 V
380 V
Minimum input voltage for rated
output
225 V
270 V
Number of MPP trackers
1
Operating input voltage range
125 ... 500 V
Maximum input current
11.5 A
Rated input current
8 A
Maximum backfeed current into
the PV generator
0 A
Maximum input power at
maximum active output power
2,560 W
3,070 W
Rated input power (cos phi = 1)
2,560 W
3,070 W
Recommended maximum PV
power
3,100 Wp
3,800 Wp
Derating / power limiting
occurs automatically when:
n
input power > max. recommended PV power
n
Cooling is inadequate
n
Input current too high
n
Grid current too high
n
Internal or external power reduction
n
Grid frequency too high (in accordance with country
setting)
n
Limiting signal on external interface
n
Output power limited (set on the inverter)
AC output side (grid connection)
Output voltage
185 V ... 276 V (depending on the country settings)
Rated output voltage
230 V
Maximum output current
14 A
Rated output current
11 A
13 A
Maximum active power (cos phi
= 1)
2,500 W
3,000 W
EN
747,431 | Z09.2 | 18/02/2016
74
Summary of Contents for coolcept StecaGrid 1500
Page 1: ...Installation and operating instructions EN coolcept coolcept x 747 431 Z09 2 2016 02 18...
Page 57: ...Fig 20 Email confirming successful registration EN 747 431 Z09 2 18 02 2016 57...
Page 85: ...Appendix EN 747 431 Z09 2 18 02 2016 85...
Page 93: ...747 431 Z09 2 2016 02 18...
Page 94: ......