n
The inverter has two RS485 interfaces (RJ45 sockets) on the
lower side of the casing.
n
The beginning and end of the RS485 bus must be terminated;
see
Chapter 3.6.5 ‘RS485 termination’ on page 28.
n
Standard RJ45 cables can be used as bus cables (Cat-5 patch
cables, not supplied). Use an alternative data connection cable
for longer connections; see
Chapter 3.6.4 ‘Alternative RS485
data connection cable’ on page 28.
n
The inverters connected to the RS485 bus operate as slaves.
Notice
The following inverters have compatible data
interfaces and can be connected to the RS485 bus as
slaves:
–
StecaGrid 2020
–
StecaGrid 1500, 1800, 2000, 2300, 2500, 3010,
3000, 3600, 4200 and StecaGrid 1500, 1800x,
2000x, 2300x, 2500x, 3010x, 3000x, 3600x,
4200x
–
StecaGrid 8000 3ph, StecaGrid 10000 3ph
–
StecaGrid 8000+ 3ph, StecaGrid 10000+ 3ph
Comply with the instructions in the manuals of these
devices relative to addressing, termination, and
approved data cables.
EN
747,431 | Z09.2 | 18/02/2016
25
Summary of Contents for coolcept StecaGrid 1500
Page 1: ...Installation and operating instructions EN coolcept coolcept x 747 431 Z09 2 2016 02 18...
Page 57: ...Fig 20 Email confirming successful registration EN 747 431 Z09 2 18 02 2016 57...
Page 85: ...Appendix EN 747 431 Z09 2 18 02 2016 85...
Page 93: ...747 431 Z09 2 2016 02 18...
Page 94: ......