4.8 Feed-in management
Depending on the country, photovoltaic systems must have the
possibility of being reduced in the fed-in effective power by the
network operator. The following products are recommended for
implementing this legally prescribed specification:
n
StecaGrid SEM
n
WEB'log from Meteocontrol
n
Solar-Log from Solare Datensysteme
n
Energy-Manager from Kiwigrid
Furthermore, an energy meter can be used for feed-in management.
It must be connected to the Modbus RTU interface and meet the
on page 29 and
Chapter 3.6.8 ‘Modbus RTU data connection
NOTICE!
The settings for feed-in management must be made
in the sub-menu 'Energy management'.
1.
Press
SET
to call up the item.
2.
Press
s
to select "Energy meter".
3.
Press
SET
.
4.
Press
ESC
to go one level higher to Energy management.
NOTICE!
The power fed into the grid is adjusted in 10 W steps.
It can be limited to a minimum of 0 W.
NOTICE!
The inverter can only work with energy meters that
have been pre-programmed in the inverter. The pre-
programmed energy meters are listed under
Meter
type
.
Mode
Dynamic feed-in
regulation
Configuration of the
energy meter
EN
747,431 | Z09.2 | 18/02/2016