Attachment 4
ANSI/BHMA and UL Compliance Requirements for Sliding Doors
(Sheet 2 of 3)
To ensure that a sliding door operates in accordance with UL 325 entrapment protection criteria the following must
be established:
• Manual opening force (sliding doors without breakout) or breakout force with power on or off must be less
then 50 lbf (222.4 N).
• Closing force must be less than 30 lbf (133.4 N).
• A closing sliding door must not develop kinetic energy in excess of 2.5 ft-lbf (3.39 J). This is achieved by proper
setting of the closing speed. See section entitled “Closing Speed”.
• Maximum recommended door weight:
• Dura-Glide 5000 Series = 150 lbs (70 kg) per panel.
• Dura-Glide/Dura-Guard/Dura-Storm and similar 2000/3000 Series = 220 lbs (100 kg) per panel.
• IS10000/Double Diamond and similar Industrial Series = 300 lbs (90 kg) per panel
Closing Speed
Closing speed is measured over a travel distance of 2 or 3 feet. On smaller bi-part doors there may only be
2 feet of movement before the door system enters close-check (latch check). The time measurement should
start once the door has achieved closing speed, usually 6 inches from full open. Mark this point on the floor
with tape or other object. Measure from this point 2 or 3 feet toward the closed position and mark the next
point. Use a stopwatch to measure the time it takes for the sliding panel to travel this distance during
normal closing cycles. Make sure the door system is not braking or entering close-check during the
measurement. Repeat the measurement 3 times and use the average value. The allowed time for a
sliding panel to cover this distance during the closing cycle is given in the table below.
Door Weight
(pounds)
Closing Time (seconds)
2 foot measurement
Closing Time (seconds)
3 foot measurement
160 or less
2.0
3.0
161 to 180
2.1
3.2
181 to 200
2.2
3.3
201 to 220
2.3
3.5
221 to 240
2.4
3.7
241 to 260
2.5
3.8
261 to 280
2.6
4.0
281 to 300
2.7
4.1
NOTE